Revolution™ ACTs

> Medical & Hospital> Diagnostic Imaging> Computerized Tomography (CT)> Revolution™ ACTs

Revolution™ ACTs


Revolution™ ACTs 

Healthcare professionals around the world face unique challenges when it comes to the optimization of space, resources and technology that delivers quality imaging and accurate diagnostics for patients, across a spectrum of clinical disciplines.

Simple and fast, CT is one of the most valuable diagnostic imaging tools in healthcare. GEHC’s new Revolution ACTs series is tailored to meet your unique needs.

Revolution™ ACTs is designed not only as a product, but as a solution to help you provide better patient care — and provide it to more patients. It’s the centerpiece of our commitment to help you achieve your CT services aims. You’ll find many of the technologies inherited from our most advanced Revolution CT system – like the new Clarity panel detector, new user interface, or ViSR dose reduction technology. Helping you feel more confident about moving to the next level, clinically and economically — that’s intelligent innovation. Revolution ACTs is available in 4 slice and 16 slice.

  • ASiR is an advanced iterative reconstruction technique that provides breakthrough image quality in multi-slice CT exams at significantly less dose than before. It allows healthcare providers to lower dose by up to 40%** to your patients as compared to standard image reconstruction without reducing imaging quality.
  • Volumetric Image Space Reconstruction (ViSR): An advanced filter helps manage photon starvation in large-size patients as well as wide or dense anatomical objects such as shoulders and pelvis. A 3D filter reduces noise without compromising resolution, for clear visualization of brain, tumor, and pediatric cases. ViSR delivers up to a 20% improvement in image quality at the same dose, or the same image quality with up to a 36% dose reduction.
  • Organ Dose Modulation (ODM): ODM was developed as a virtual shield and to provide the dose reduction goal of a shield material, without the negative effects it might have on imaging performance. Reduce radiation does up to 40% when imaging superficial tissues such as breasts and the eyes.
  • Dose Check - for more peace of mind: Receiving notifications and alerts if your predetermined dose levels will be exceeded enables you to correct and confirm the right settings before scanning to avoid unnecessary radiation dose to your patient.
  • 3D mA Modulation - the right dose for each individual: This feature enables the system to optimize tube current in x-y and z directions with negligable effect on the image quality. The system varies mA according to the patient shape and scan protocol to lower dose in a patient-centric manner.
  • DoseWatch™ - effectively manage dose over time: With this comprehensive dose management solution, you can keep dose levels as low as is reasonably achievable (ALARA) while producing sharp, focused diagnostic images. Track and monitor patients’ cumulative radiation dose over time and take steps to prevent an excessive radiation dose.